Many of the faults on Viking’s DFUD dishwashers refer to the pressure sensor, the part that reads how much water is in the sump. F6 (the sixth LED, L6) is not about the water at all. It is about the sensor’s own electrical signal: the output has gone above 4.8 V.
Effect on the cycle
The program continues. The manual states that this one is indicated only in the service menu, so a normal user would not see a code on the panel. The importance is that the dishwasher relies on the same sensor for level decisions in other places, as the filter and circulation faults show.
Where the manual points
| Item to check | Role |
|---|---|
| Pressure sensor | Measures the water level through the pressure chamber |
| Control unit | Receives and interprets the signal |
| Wiring | Carries the signal between the two |
Owner’s view
There is no reset step in the manual and no item for the owner to inspect. A voltage reading is a meter job, done on a machine that is powered and open, which is not something to attempt at home. If you only learned of the code because a technician read it in the service menu, it is worth asking whether other pressure-based codes appeared as well.
Pressure-sensor family
- F8: excessively low pressure in the final rinse, reported after the program ends
- F9: pressure too low or too high during circulation
- 2-1: the pressure sensor reading out of range on the newer models