An oven control needs to know what oven it is in. In Viking’s EOC4 system, the model header provides that identity, and F06 is the control saying the header is undefined. The sheet adds that this is read only at power-up, so the problem declares itself the moment power is applied rather than during a cycle.
Results
- The EOC4 will be inoperable. There is no cook or clean mode to fall back on.
- Priority A, a critical error under the sheet’s key.
- Ranges: Clean light on and Cycle light flashing twice.
- Wall ovens with TOD2 or TOD3: F06 on the display.
A fault of setup, not use
The sheet says only that the model header is undefined. The sheet’s remedy is for a technician: power down and insert the correct model header.
What the owner can do
The sheet offers no owner reset for F06. Opening the control to look for the header means working near live parts, so leave it to the technician.
Other power-up and control codes
- F08: the serial link between the control and the user interface is lost
- F03: the cooling fan signal is missing
Viking range service in San Francisco
Call (415) 917-1863 for Viking range service in San Francisco. Say F06 appeared at power-up, and mention whether any control work was done recently.
Technical sources
- Viking EOC4 Fail Codes (Ranges - Ovens) fail-code sheet, hosted on uncleharrywizard.com — http://www.uncleharrywizard.com/nephewclub/wizardrange/viking/programming-and-diagnostic/EOC%204%20Error%20Codes.pdf