What triggered it
Nothing is broken when F10 appears on an EOC4-controlled Viking. The control logs it when someone tries to program a delayed self-clean, meaning a clean set to begin later rather than right away. The oven does not permit that combination, so it shuts down and goes into error mode.
Where it shows
Wall ovens with a TOD2 or TOD3 clock print F10 on the display. Ranges use lights: Clean on, with the Cycle light flashing 10 times.
The fix, step by step
- Cancel the cycle and turn the oven off.
- Clear the error by powering the oven down, then set the control back up for a normal self-clean, which is what the sheet lists as the reset.
- Start the self-clean as an immediate cycle with no delay start.
Heat and fumes from a clean cycle are normal, so run the kitchen fan and keep pets out of the room.
When it is more than a mistake
If F10 returns when you did not set a delayed clean, or the oven will not accept an ordinary clean either, call for service. The sheet lists this as a Priority A error, which cancels the current cycle and turns off all elements, so the oven will not carry on until the code is cleared.
Other self-clean related codes
- F01: the door lock is not where it should be during cooking or cleaning
- F07: door open during a clean cycle
Help from our San Francisco office
If a normal self-clean will not start either, ring (415) 917-1863 and tell us what you pressed before F10 appeared.
Technical sources
- Viking EOC4 Fail Codes (Ranges - Ovens) fail-code sheet, hosted on uncleharrywizard.com — http://www.uncleharrywizard.com/nephewclub/wizardrange/viking/programming-and-diagnostic/EOC%204%20Error%20Codes.pdf