Error codes
Viking error codes, by platform
Viking does not use one universal code dictionary. Refrigeration E1 means different things on different controls, oven F1 is not F01, and cooktop FC is not Fc. Find the code for your appliance — and photograph the display before you reset.
- Error-code records
- 72
- Appliance types
- 4
- Model records
- 164
Dishwasher
- 1-1The moisture sensor in the base pan reads out of its normal range, which Viking links to disconnected wires, a defective sensor or a defective control board.
- 1-2The motor control reports a wash-motor failure or the motor current is out of range, traced to wiring, the motor, the motor control or the start capacitor depending on the model.
- 1-3The main control cannot successfully communicate with the motor control.
- 1-4The main control activates the diverter but never receives feedback that the correct position has been reached.
- 1-5The control found water remaining after a drain; the pressure sensor never reached the empty level or the water-detection routine saw water left in the tub.
- 2-1The pressure sensor reads out of its normal range on the low side.
- 2-2A fill error: the pressure sensor does not reach target fill pressure during a fill, or on non-pressure-sensor models the temperature change expected during filling does not occur.
- 2-3The pressure sensor indicates a water level below the low-level threshold.
- 2-4The pressure sensor indicates a water level above the high-level threshold.
- 2-5An abnormal pressure-sensor change: the water drains too fast or fills too fast.
- 3-1The user interface is unable to communicate with the main control.
- 3-2The control detects insufficient or inconsistent water flow through the wash system and will not allow the flow-through heater to activate.
- 3-3Drain pump current sense is out of range.
- 3-4The motor control reports a motor operation failure most likely caused by the motor.
- 3-5The motor control reports a low motor control voltage condition.
- 4-1The temperature sensor reads out of range, from disconnected wires, a defective sensor or a defective control board.
- 4-2Wash heater current sense is out of range.
- 4-3Dispenser current sense is out of range.
- 4-4Inlet valve current sense is out of range.
- 4-5The pressure sensor reaches the fill level too fast, an abnormal pressure-sensor change.
- 5-1Vent current sense is out of range.
- 5-2Blower current sense is out of range.
- 5-3Dry heater current sense is out of range; the VDB451 manual lists it as N/A on the 451.
- 5-4The main control reads current draw when no loads are active.
- 5-5The main control or user interface detects a board-level failure.
- ALL LEDS BUT START FLASH / AC POWER LOSSAll LEDs except Start (and Run on some models) flash continuously because AC power was lost during a running cycle.
- BOTH LEDS FLASH / PAN MOISTUREBoth LED1 and LED2 flash continuously because the base pan moisture sensor detects water, from an overflow, a leak or a defective sensor.
- F1 / L1Water temperature rose by less than 50F in five minutes, so the program skipped out of the heating stage and continued.
- F2 / L2Too much water in the machine, sensed by the pressure sensor or the float; if not drained within 60 seconds the program is interrupted and the drain pump runs.
- F3 / L3The thermistor is interrupted or reads above 176F; the program leaves the heating stage and continues, and the fault is shown only in the service menu.
- F4 / L4Fewer than 80 water pulses in 60 seconds, or the correct pulse count not reached within 255 seconds, so the program is interrupted.
- F5 / L5More than 80 pulses were detected while the inlet valve was deactivated; the running program is interrupted and the drain pump runs.
- F6 / L6The pressure sensor output signal is above 4.8 V; the program continues and the fault is shown only in the service menu.
- F7 / L1+L2Water was not evacuated after 120 seconds of pumping out, so the program is interrupted.
- F8 / L1+L3The pressure sensor senses excessively low pressure during the final rinse; the fault is indicated after the end of the program.
- F9 / L1+L4The pressure sensor reads excessively low or high pressure; the program leaves the heating stage and continues, and the fault is shown only in the service menu.
- Fb / L1+L6The spray arm divider position contact is continuously closed or open; the program proceeds and the fault is shown only in the service menu.
Induction Cooktop
- 1 FLASHOne flash with a brief interval between flashes means the internal power device is over temperature.
- 2 FLASHESTwo consecutive flashes mean an internal power device malfunction.
- 3 FLASHESThree consecutive flashes mean a malfunction of the power device temperature sensor.
- 4 FLASHESFour consecutive flashes mean a coil temperature sensor malfunction.
- 5 FLASHESFive consecutive flashes mean the inside ambient temperature is too high.
- 6 FLASHESSix consecutive flashes mean the cookware is incompatible with induction; if flashing continues after adjusting cookware, call service.
- Er47 / 5 flashes then pauseLEDs flash five times then pause and the seven-digit display shows Er47 because the interface adapter board has the wrong configuration program (C1-C6).
Oven
- F01The door lock is not at the unlocked position during a cook or at the locked position during a clean; a critical (priority A) fault.
- F02The RTD (oven temperature sensor) is open or shorted; cook and clean cycles are cancelled and the EOC4 control is inoperable.
- F03The EOC4 control is not receiving a square wave in the allowable frequency range from the cooling fan Hall-effect sensor; bake or clean is cancelled immediately.
- F04The meat probe input is shorted; cook-by-probe operation is cancelled (priority B, non-critical).
- F06The model header is undefined; it is read only at power-up and the EOC4 control is inoperable.
- F07The door is open during CLEAN, because the latch or door sensor failed or the door was opened right after selecting CLEAN; a critical (priority A) fault.
- F08The RS485 serial link between the EOC4 control and the user interface is lost or cannot be established.
- F09The control detected temperature above the 650F limit for more than 10 minutes with the door unlocked and went into error mode.
- F10A delayed self-clean cycle was attempted, which the EOC4 control does not accept; it shuts down into error mode.
- NO PROBEThe meat probe is open or removed during a cook-by-probe function; the oven cancels probe cooking.
- F1A control malfunction detected inside the electronic range control (ERC); the service manual says to replace the ERC.
- F2Oven over temperature; the service manual says to check the sensor wiring, the sensor and the temperature limiter.
- F21The TOD2 detects one or more keys shorted for longer than 1 minute and cancels any timed cycle or delay start.
- F3Open oven sensor or sensor circuit; the manual says to check sensor resistance and wiring.
- F4Shorted oven sensor or sensor circuit; the manual says to check sensor resistance and wiring.
- F7Shorted input key (touch pad / control panel to board connection); the manual says to verify the connection, test panel continuity and replace the control panel.
- F9Door lock failure: the lock switch sensing reports the door unlocked; the manual says to check the latch switch, door motor, plunger switch and wiring.
- FFDoor lock failure: the lock switch sensing reports the door locked; the manual says to check the latch switch, door motor, plunger switch and wiring.
Refrigerator
- oPnThe display shows oPn with an audible alarm; this is the temperature sensor alarm, indicating a sensor problem.
- ShrThe display shows Shr with an audible alarm; this is the temperature sensor alarm, indicating a sensor problem.
- OPIn service test mode on the VCFF/DDFF136D, OP in a thermistor test (141, 142, 144, 145) means the thermistor reads open.
- SHIn service test mode on the VCFF/DDFF136D, SH in a thermistor test (141, 142, 144, 145) means the thermistor reads shorted.
- BLUEZONEThe thin blue Bluezone indicator strip shows along the bottom of the display when the Bluezone bulb needs replacement, about every two years.
- CLThe refrigerator temperature display blinks CL when it is time to clean the condenser coil.
- HIGH TEMPERATURE ALARMThe alarm sounds and the display flashes when the refrigerator or freezer temperature exceeds the allowed high temperature.
- LONG TERM POWER LOSSAfter a long-term power loss the display shows a power-loss indication; pressing any key clears it.
- OPEN DOOR ALARMThe alarm sounds when a door or drawer stays open longer than 3 minutes.
- WATER FILTERThe FILTER button illuminates blue when it is time to change the water filter.
No verified record for that code. Some displays are maintenance indicators — send a photo of the display with your model number and we’ll check it.

Ready to get your Viking appliance working again?
Book online or call — you get a written estimate and approve it before any repair work starts.
Book a repair
Tell us what’s wrong — we’ll handle the rest
Share a few details and we’ll confirm an appointment window. Prefer to talk? Call and we’ll help right away.
- Phone(415) 917-1863
- Email[email protected]
- HoursMon–Sat: 8:00 AM – 7:00 PM
- Service areaSan Francisco Bay Area, California
Request your repair
Prefer to talk? Call (415) 917-1863.